1.
The device that serves as the main control center of a fire alarm system.
2.
This Lag occurs when the physical properties of the Heat detector cause it to lag behind the alarm condition of the surrounding air.
3.
This controller serves as the “brains” of the fire alarm system.
4.
Soft-toned appliances used where loud noises could be disruptive to other operations.
5.
A circuit connects automatic or manual initiating devices without identifying the individual device that operated.
6.
An applicance fire alarm component provides audible, tactile, or visible output to occupants.
7.
It is a circuit or path directly connected to notification appliances.
8.
Stations have an inhibit device that must be damaged to activate the station (non-ADA compliant).
9.
The element of the fire triangle can include gases, liquids, and solids such as gasoline, wood, paper, and propane.
10.
The stage of fire produces products of combustion particles smaller than 0.3 microns with no visible smoke or detectable heat.
11.
The stage produces visible smoke particles with little visible flame or noticeable heat.
12.
The stage involves rapid combustion that produces radiant energy in visible, infrared, and ultraviolet spectrums.
13.
A type of smoke detector reacts more quickly to fast flaming fires that give off little smoke.
14.
A type of smoke detector uses light scattering or light obscuration to detect smoke.
15.
The type of automatic detector provides detection at a particular location, such as a heat or smoke detector.
16.
A type of detector provides continuous detection along a path, such as thermal cable or beam detectors.
17.
The detection system draws air through pipes into an enclosed chamber for testing.
18.
The fuel, heat and oxygen are all needed in the right combination in order to produce this one.
19.
The type of automatic fire detection device alarms when a specified temperature condition is reached.
20.
A heat detector responds when the rate of temperature increase exceeds an allowable limit.
21.
The cable line-type initiating device uses heat-sensitive insulation that softens at a rated temperature, allowing two wires to make electrical contact.
22.
A visual notification appliance is commonly used in high-noise environments and areas occupied by hearing-impaired individuals.
23.
The type of power supplies the fire alarm system when primary AC power is lost.
24.
A detector sprinkler monitoring device reacts to water flow equivalent to approximately one sprinkler head activating.
25.
A switch supervisory device monitors critical sprinkler control valves and generates a supervisory alarm when a valve is shut off.